Home    Water cooling equipment    Closed cooling tower    Closed Cooling Tower
WechatIMG1190
闭式双循环10t
15t冷却塔
_mg_1039

Closed Cooling Tower

Closed cooling tower

Closed cooling towers (also called fluid coolers and adiabatic cooling towers) pass the working coolant through a large heat exchanger (usually a radiator), upon which clean water is sprayed and a fan-induced draft applied. The resulting heat transfer performance is close to that of a wet cooling tower, with the advantage of protecting the working fluid from environmental exposure and contamination. Alternatively the water is sprayed into the incoming air or supplied into "fill media" to cool the air before it passes to the radiators.

 

When the system works, the process fluid requiring cooling flows inside the serpentine heat exchanger coil with a spray system outside to continuously wet the coil surface.

 

The water sprayed onto the coil is cooled by a radiator with efficient cooling effect and then falls to the sink plate for recycling.

The system adopts advanced reverse current technology, the air is inhaled simultaneously and through the coil and radiator, so that a part of the water evaporation.All moisture contained in the air stream is recovered by the splash water baffle and returned to the catchment plate.

 

The evaporation takes the heat from the spray water before cooling the process fluid in the coil and coil.

 

In this process, the only water component "consumed" the drop plus a fraction of the effluent, which suppresses the concentration of impurities in the recycled water.

 

The closed cooling tower is actually a combination of evaporative cooling tower, cooler and wet cooling tower, it is a horizontal evaporative cooling tower, process fluid flow through the pipe, air flows through the pipe, the two do not contact each other.Closed cooling tower is a kind of deformation and development of the traditional cooling tower.The water in the tower reservoir is drawn from the circulating pump and sent to spray down evenly outside the pipe.Is not in contact with the process fluid hot water or refrigerant and outside the pipe air, and becomes a closed cooling tower, which enhances the effect of heat transfer and quality transfer by spraying water. Closed cooling towers are suitable for various cooling systems requiring high circulating water quality and have potential applications in the power, chemical, steel, food and many industrial sectors.

 

On the other hand, compared with the air-cooled heat exchanger, the evaporative cooling tower uses the evaporation potential heat of the water side of the pipe to significantly enhance the heat transfer on the air side, which also has significant advantages.

 

Model

Cooling capacity(m3/h)

Fan

Spray pump

 

Water Inlet/Outlet DN(mm)

Water Pressure(Mpa)

Weight

(Kg)

Dimension

mm )L×W×H

 

 

power(kw)

Air capacity(m3/h)

power(kw)

flow rate(m3/h)

 

 

 

 

HTBF-15

15

0.9

20000

1.1

22

65

0.2

465

2350*1000*1850

HTBF-20

20

0.9

20000

1.1

22

65

0.25

490

2350*1000*1920

HTBF-30

30

1.5

26000

1.5

25

65

0.25

650

2850*1250*2100

HTBF-40

40

2.6

33600

1.1

22

80

0.3

750

2850*1250*2300

HTBF-50

50

2.6

33600

1.5

25

80

0.3

980

2850*1250*2650

HTBF-60

60

3.6

40000

1.5

25

80

0.3

1050

2850*1250*2800

HTBF-70

70

3.6

40000

2.2

44

100

0.35

1280

2850*1500*2750

HTBF-80

80

3

52000

2.2

44

100

0.35

1450

2850*1660*2990

HTBF-100

100

3

52000

2.2

44

100

0.35

1945

2850*1660*2990

HTBF-125

125

5.2

67200

4

88

125

0.35

2450

2850*1660*2950

HTBF-150

150

7.2

80000

4

88

150

0.35

2850

3350*1880*2960

HTBF-175

175

7.8

100800

4

88

150

0.35

3150

3950*1880*3100

HTBF-200

200

10.8

120000

4

140

200

0.35

3600

4350*2080*3100

HTBF-250

250

14.4

160000

4

140

200

0.5

4900

4850*2160*3300

HTBF-300

300

17.6

196000

4

140

200

0.5

5700

5250*2310*3700

HTBF-350

350

15.6

201600

4×2

176

150×2

0.5

6300

5850*2310*3700

HTBF-400

400

21.6

240000

5.5×2

200

150×2

0.6

7200

6000*2440*3800

HTBF-450

450

25.2

280000

5.5×2

200

200×2

0.6

9450

6000*2440*3800

HTBF-500

500

28.2

320000

7.5×2

298

200×2

0.6

9800

5000*4850*3550

 

Application:

1.  cool down the temperature of melting furnace to assure the melting furnace running well

2.  cool down the power cabinet to assure the circuit under good condition

3.  remove the heat in foundry,metal casting etc.

 

Features and Advantages:

Keep the process fluid free from contamination.

Reduce the possibility of scaling.

Reduce the system energy consumption cost.

Reduce the system maintenance costs.

Ensure the reliable and efficient operation of the equipment throughout the year

Use demineralized water as the coolant, do not contact with air, do not deteriorate and scale, to ensure the best cooling effect.

Low loss of circulating water

There are water collector on the spray system for water collection and fog collection with less water consumption.

Convenient disassembly and assembly, low operation costs and low maintenance costs.

Compact structure, small land occupied and convenient installation.

Less quick-wear parts, low failure rate, convenient maintenance.

Intelligent control, energy saving and environmental protection.

Your Name

E-mail *

Phone *

Company

Subject

Content *